Bipolar cautery versus conventional suture ligation of vascular pedicles in thyroidectomy: a comparative clinical study

Authors

  • Om Prakash Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Chandrashekar S. Department of Biostatistics, AIIMS, New Delhi, India
  • Jency Mattews Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Robinson George Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Suprej K.
  • James Mattew Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Filsy Lilly Francis Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Flora Rachel Shajan Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Jincy Alex Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India
  • Gokul D. Kamath Department of General Surgery, Pushpagiri Institute of Medical Sciences and Research Centre, Thiruvalla, Kerala, India

DOI:

https://doi.org/10.18203/2349-2902.isj20211294

Keywords:

Bipolar cautery, Thyroidectomy, Sutureless thyroidectomy

Abstract

Background:  Thyroidectomies are commonly performed surgeries worldwide. With better knowledge of anatomy and major advent of energy devices, morbidity of thyroidectomy has drastically declined. Two main globally followed procedures to deal with vascular pedicles are conventional suture ligation and electro cautery devices. The objectives of the present study are to compare classical suture ligation and bipolar cautery of vascular pedicles in thyroidectomy, in terms of duration of procedure, hospitalization and operative complications.

Methods: Retrospective observational comparative study was conducted in 100 patients who underwent total thyroidectomy in our institution for a period of 3 years from 4 September 2017. Non random sampling techniques applied on all consecutive patients who are eligible according to the inclusion criteria. Patients divided into two groups used: suture ligation (n=50), bipolar cauterization (n=50). The main outcomes measured were surgical and hospitalization time; duration of wound drain and post-operative complications (hoarseness, hypocalcemia and seroma).Student t test (for quantitative) and Chi Squaretest (for qualitative) applied for analysis.

Results: Post-operative complications are present more in the suture ligation group (66%) compared to bipolar cautery (24%). The procedure time in ligation is a 131.6±17.7 minutes which is, significantly higher compared to bipolar cautery (97±7.5 minutes). Duration of hospital stay is more in suture ligation (6±0.8 days) compared to bipolar cautery (4.9±1.3 days).

Conclusions: As per our study, bipolar cauterization has significant reduction of surgery time, duration of hospital stay and postoperative complications viz seroma, hoarseness of voice, hypocalcemia compared to conventional suture ligation.

References

Vesely DL, Angtuaco EJ, Boyd CM. Sinus tract in the neck: a rare complication of subtotal thyroidectomy for Graves’ disease. J Med. 1986;17 (3-4):253-61.

Bailey and Love’s short practice of surgery, the principles of diathermy. 26th ed. USA: CRC Press; 2013.

Dujovny M, Vas R, Osgood CP. Bipolar jeweler forceps with automatic irrigation for coagulation in microsurgery. Plast Reconstr Surg. 1975;56:585-91.

Malis LI. Electrosurgery and bipolar technology. Neurosurg. 2006;58(Suppl 1):1-12.

Challa S, Surapaneni S. Suture less thyroidectomy vascular control using bipolar electro thermal cautery. J Evol Med Dent Sci. 2012;1(6):1083-6.

Khafagy A, Abdelnaby I. Total thyroidectomy: LigaSure versus clamp and knot technique for intraoperative hemostasis, Egypt J Ear Nose Throat Allied Sci. 2013;14:59e657.

Govindaraj E, Meti RM, Ravikiran HR. A study of use of bipolar cautery in thyroidectomy for coagulating vascular pedicles instead of conventional ligation. Inter J Biomed Res. 2015;6 (6):382-4.

Manouras A, Markogiannakis H, Koutras AS. Thyroid surgery: comparison between the electro thermal bipolar vessel sealing system, harmonic scalpel and classic suture ligation. Am J Surg. 2008;195(1):48-52.

Sandonato L, Cipolla C, Graceffa G, Fricano S, Li Petri S, Prinzi G, et al. Bipolar electro thermic coagulation (ligasure bipolar vessel sealing system) in thyroid surgery. Chir Ital. 2003;55(3):411-5.

Bove A, Papanikolaou IG, Bongarzoni G, Mattei PA, Markogiannakis H, Chatzipetrou M, et al. Thyroid surgery with harmonic focus, ligasure precise and conventional technique: a retrospective case-matched study. Hippokratia. 2012;16(2):154-9

Rajendran CV, Gejoe G, Rajeshkumar R, Unnikrishnan G. Sutureless thyroidectomy using bipolar diathermy and hypocalcemia-A comparative study in a tertiary care centre. Journal of medical sciences and clinical research. 2017;5(1):15450-6.

Saint MO, Cogliandolo A, Piquard A, Famà F, Pidoto RR. Liga Surevs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study. Arch Surg. 2007;142(2):150-6.

Vasuki R, Thanmaran NB, Malathi V, Kujur L. A study of use of bipolar cautery in thyroidectomy. Int Surg J. 2017;4:1059-64.

Barbaros U, Erbil Y, Bozbora A, Deveci U, Aksakal N, Dinççag A. The use of Liga Sure in patients with hyperthyroidism. Langenbecks Arch Surg. 2006; 391(6):575-9.

Downloads

Published

2021-03-26

Issue

Section

Original Research Articles