A prospective study of diathermy versus scalpel skin incision in abdominal surgery

Authors

  • Arun Kumar Gupta Department of Surgery, SGRD University, Amritsar, Punjab, India
  • Tejinder Singh Dall Department of Surgery, SGRD University, Amritsar, Punjab, India
  • Darpan Bansal Department of Surgery, SGRD University, Amritsar, Punjab, India

DOI:

https://doi.org/10.18203/2349-2902.isj20194174

Keywords:

Diathermy, Scalpel, Skin incision

Abstract

Background: Various methods of skin incision have been identified in the recent past. Traditional skin incisions were made with stainless steel scalpel but recently electrocautery instruments like harmonic scalpel are also in use. With rise of seropositive cases, we aimed to evaluate whether the electrocautery can replace scalpel in operation theater, to avoid unfortunate injury to surgeons with scalpel. So we compared the usefulness of diathermy skin incision vs. scalpel skin incision in general surgical patients.

Methods: This prospective study designed to include 120 patients admitted in the Department of General Surgery, Sri Guru Ram Das Institute of Medical Sciences and Research, Vallah, Sri Amritsar and who were undergoing elective abdominal surgical procedures namely cholecystectomy, appendectomy and inguinal hernia repair etc. Patients were randomly allocated into 2 groups of 60 patients each. In Group A, incision were made with electrocautery on cut mode and power set to 60-70. In group B, skin incisions were made with scalpel.

Results: No statistical difference was found between group A and group B with regard to time of administration of pain killer injection, seroma formation, discharge being noticed from wound in both groups. Moreover the results were statistically non-significant for vascularity, pigmentation and pliability of wound observed.

Conclusions: We concluded that electrocautery can effectively and efficiently replace scalpel in operation theater.

References

Dixon AR, Watkin DF. Electrosurgical skin incision versus conventional scalpel: a prospective trial. J Royal Coll Surgeons Edinburgh. 1990;35:299-301.

Shamim M. Diathermy VS. Scalpel skin incisions in general surgery: double-blind, randomized, clinical trial. World J Surg. 2009;33:1594-9.

Aird LN, Bristol SG, Phang PT, Raval MJ, Brown CJ. Randomized double‐blind trial comparing the cosmetic outcome of cutting diathermy versus scalpel for skin incisions. Br J Surg. 2015;102:489-94.

Peterson A. The use of electrosurgery in reconstructive and cosmetic maxillofacial surgery. Dental Clin North Am. 1982;26:799-823.

Mann W, Klippel CH. Electrosurgical skin incision. J Pediatr Surg. 1977;12:725–6.

Kamer FM, Cohen A. High frequency needle dissection rhytidectomy. Laryngoscope. 1985;95:1118-20.

Tobin HA. Electrosurgical blepharoplasty: a technique that questions conventional concepts of fat compartmentalisation. Ann Plastic Surg. 1985;14:59-63.

Longaker MT. Gurtner, Geoffrey C. Diathermy or Surgical Scalpel for Abdominal Skin Incisions: What Is the Impact On Clinical Practice? Ann Surg. 2011;253;14-5.

Özgün H, Tuncyurek P, Boylu S, Erpek H, Yenisey C, Köse H, et al. The right method for midline laparotomy: what is the best choice for wound healing? Acta Chirurgica Belgica. 2007;107:682-6.

Ghansham. Incision Pain: A Comparison Between Use of Diathermy Versus Scalpel in Patients Undergoing Elective Abdominal Surgery. J Surg Pak. 2016;21:54–7.

Shivagouda P, Gogeri BV, Godhi AS, Metgud SC. Prospective randomized control trial comparing the efficacy of diathermy incision versus scalpel incision over skin in patients undergoing inguinal hernia repair. Recent Res Sci Tech. 2010;2:44-7.

Kadyan B, Chavan S, Mann M, Punia P, Tekade S. A prospective study comparing diathermy and steel scalpel in abdominal incisions. Med J DY Patil Univ. 2014;7:558-63.

Downloads

Published

2019-09-26

Issue

Section

Original Research Articles