Abstract

The forearm occupies a unique position in reconstructive practice: it is simultaneously the most frequent donor site for the radial forearm free flap and a common recipient bed for coverage of distal forearm and hand defects, and its 1–3 mm-caliber arteries and veins are the same vessels an angiologist evaluates when assessing perfusion, patency, or thrombotic risk in trauma and vascular disease. Yet the literature on forearm microvascular anastomosis is almost exclusively written from a reconstructive-surgical vantage point, with the hemodynamic and vessel-wall principles that govern patency treated as background rather than as an explicit angiologic framework. This narrative review synthesizes current evidence on suture-based anastomosis, mechanical coupling devices, venous salvage strategies, and emerging robotic and sutureless technologies in forearm and wrist microsurgery, and reframes each of these techniques against the hemodynamic and vascular-biology principles that are the traditional domain of angiology. Hand-sewn interrupted suture remains the reference technique, but systematic comparisons of suture configurations have found no consistent patency advantage of one over another, and continuous through-the-lumen suturing has achieved comparable patency with shorter execution time despite theoretical concerns about intraluminal thrombogenicity. Mechanical coupling devices have reduced anastomotic time and, for venous anastomosis specifically, have been associated with low thrombosis rates in large pooled series; arterial coupling remains more contested because arterial wall thickness, medial stiffness, and, in older or vasculopathic patients, atherosclerotic change increase the risk of intimal disruption and thrombosis — concerns that are fundamentally angiologic rather than purely technical. Venous outflow failure remains the leading cause of flap compromise in severe forearm and hand trauma, prompting salvage strategies such as dual venous anastomosis and a bone-anchored coupler technique that repurposes vascularized bone marrow as a recipient venous bed when conventional veins are unavailable. Robotic-assisted anastomosis and sutureless adjuncts show patency comparable to manual technique but remain limited by longer operative times and an immature evidence base. We argue that closer integration of angiologic assessment — vessel wall quality, flow dynamics, and pre-operative vascular mapping — into reconstructive planning may reduce technique-dependent failure and should be considered a natural extension, rather than a separate discipline, of forearm microsurgery.

References

Song R, Gao Y, Song Y, Yu Y, Song Y. The forearm flap. Clin Plast Surg. 1982;9(1):21-6.

Soutar DS, Scheker LR, Tanner NS, McGregor IA. The radial forearm flap: a versatile method for intra-oral reconstruction. Br J Plast Surg. 1983;36(1):1-8.

Godina M. Early microsurgical reconstruction of complex trauma of the extremities. Plast Reconstr Surg. 1986;78(3):285-92.

Vater AM, Aitzetmüller-Klietz MM, Lamby PE, Stanger J, Meffert R, Schmidt K, et al. Microvascular ALT-flap reconstruction for distal forearm and hand defects: outcomes and single-case application of a bone-anchored venous anastomosis. J Clin Med. 2025;14(19):6807.

Malek AM, Alper SL, Izumo S. Hemodynamic shear stress and its role in atherosclerosis. JAMA. 1999;282(21):2035-42.

Chiu JJ, Chien S. Effects of disturbed flow on vascular endothelium: pathophysiological basis and clinical perspectives. Physiol Rev. 2011;91(1):327-87.

Hanasono MM, Butler CE. Prevention and treatment of thrombosis in microvascular surgery. J Reconstr Microsurg. 2008;24(5):305-14.

Wang M, Guo H, Zhang G, Ruan P, Zhi K. Development and innovation of modern microvascular anastomoses. J Biosci Med. 2024;12:10.

Quach MP, Zona EE, Orgun D, Thao P, Gupta S, Furtado NJ, et al. Microvascular anastomosis devices: a scoping review. J Reconstr Microsurg. 2026;10.

Alghoul MS, Gordon CR, Yetman R, Buncke GM, Siemionow M, Afifi AM, et al. From simple interrupted to complex spiral: a systematic review of various suture techniques for microvascular anastomoses. Microsurgery. 2011;31(1):72-80.

Maruccia M, Fatigato G, Elia R, Ragusa LA, Vestita MG, Nacchiero E, et al. Microvascular coupler device versus hand-sewn venous anastomosis: a systematic review of the literature and data meta-analysis. Microsurgery. 2020;40(5):608-17.

Lai CS, Lu CT, Liu SA, Tsai YC, Chen YW, Chen I. Robot-assisted microvascular anastomosis in head and neck free flap reconstruction: preliminary experiences and results. Microsurgery. 2019;39(8):715-20.

Pafitanis G, Nicolaides M, O’Connor EF, Raveendran M, Ermogenous P, Psaras G, et al. Microvascular anastomotic arterial coupling: a systematic review. J Plast Reconstr Aesthet Surg. 2021;74(6):1286-302.

Jarvis MA, Jarvis CL, Jones PR, Spyt TJ. Reliability of Allen’s test in selection of patients for radial artery harvest. Ann Thorac Surg. 2000;70(4):1362-5.

Yasmeen S, Rahman OU, Khan MI, Anwar R, Tahir H. Continuous through-the-lumen microvascular anastomosis: a retrospective review of a modified technique. Plast Reconstr Surg Glob Open. 2025;13(9):e7128.

Jandali S, Wu LC, Vega SJ, Kovach SJ, Serletti JM. 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction. Plast Reconstr Surg. 2010;125(3):792-8.

Grewal AS, Erovic B, Strumas N, Enepekides DJ, Higgins KM. The utility of the microvascular anastomotic coupler in free tissue transfer. Can J Plast Surg. 2012;20(2):98-102.

Ardehali B, Morritt AN, Jain A. Systematic review: anastomotic microvascular device. J Plast Reconstr Aesthet Surg. 2014;67(6):752-5.

Mai TT, Nguyen LTT, Nguyen PD. Efficiency and safety of microvascular anastomotic coupler for wrist revascularization in traumatic injuries. JPRAS Open. 2024;41:252-9.

Xia L, Xu YB, Zhao J, Li P, Huang L. Clinical efficacy of microvascular anastomotic coupler in upper limb replantation. Hand (N Y). 2016;11(1 Suppl):74S.

Chernichenko N, Ross DA, Shin J, Chow JY, Sasaki CT, Ariyan S. Arterial coupling for microvascular free tissue transfer. Otolaryngol Head Neck Surg. 2008;138(5):614-8.

Frederick JW, Sweeny L, Carroll W, Rosenthal E. Microvascular anastomotic coupler assessment in head and neck reconstruction. Otolaryngol Head Neck Surg. 2013;149(1):67-70.

Gundale AR, Berkovic YJ, Entezami P, Nathan CO, Chang BA. Systematic review of microvascular coupling devices for arterial anastomoses in free tissue transfer. Laryngoscope Investig Otolaryngol. 2020;5(4):683-8.

Bui DT, Cordeiro PG, Hu QY, Disa JJ, Pusic A, Mehrara BJ. Free flap reexploration: indications, treatment, and outcomes in 1193 free flaps. Plast Reconstr Surg. 2007;119(7):2092-100.

Riccardo N, Carlotta M, Guido L, Esmeralda Z, Arsie AE, Gabriele M, et al. Management of the venous anastomoses of a tertiary referral centre in reconstructive microvascular surgery using fasciocutaneous free flaps in the head and neck. J Clin Med. 2025;14(17):6171.

Malzone G, Menichini G, Innocenti M, Ballestín A. Microsurgical robotic system enables the performance of microvascular anastomoses: a randomized in vivo preclinical trial. Sci Rep. 2023;13.

Eșanu V, Marziali E, Gaspar O, Agoston S, Carciumaru T, Stoia A, et al. Microvascular errors of technique: a systematic review. Acta Neurochir (Wien). 2026;168(1):65.

Downloads

Published

2026-11-25

How to Cite

Gómez, D. E. G. (2026). Microvascular anastomosis of the forearm: a narrative review . International Surgery Journal, 13(12), 2660–2665. https://doi.org/10.18203/2349-2902.isj20264383

Issue

Section

Review Articles