Endovascular management of a giant thoracic aortic aneurysm sac rupture due to type IB endoleak with a pre-established iliac conduit
DOI:
https://doi.org/10.18203/2349-2902.isj20264369Keywords:
Aortic aneurysm, Type IB endoleak, Aneurysm rupture, Iliac conduit, EndovascularAbstract
Endoleaks are the most common post-TEVAR complication, clinically relevant due to the risk of persistent pressurization of the aneurysmal sac and hence rupture with mortality ranging from 44% to 100%. TEVAR requires delivery systems ranging from 18 Fr to 24 Fr, sometimes needing the creation of an iliac conduit using whether open or endovascular techniques. Repeatedly used iliac conduit grafts may lead to further local increased difficulty for their manipulation or use for future procedures. We present the case of a 64-year-old man presenting to the emergency department due to thoracic pain. He had two previous endovascular aortic aneurysm repairs (thoracic and abdominal). The contrast-enhanced Computed Tomographic scan revealed a type 1B endoleak in the descending aorta with an 11.5 cm aortic sac diameter enlargement which had a spontaneous rupture 4 days after admission, requiring an emergency management using a previous iliac conduit which had been used two times before leading to a hostile anatomic area, and hemothorax drainage. This case highlights the importance of close monitoring after any endovascular aortic repair due to the risk of stent-graft associated complications like endoleaks and their consequences, as well as the importance of the creation of a successful permanent vascular access through iliac conduits due to the possibility of further procedures.
References
Coady MA, Ikonomidis JS, Cheung AT, Matsumoto AH, Dake MD, Chaikof EL, et al. Surgical management of descending thoracic aortic disease: open and endovascular approaches: a scientific statement from the American Heart Association. Circulation. 2010;121(25):2780-804.
Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994;331(26):1729-34.
Tanious A, Boitano L, Canha L, Chou EL, Wang LJ, Latz C, et al. Thoracic aortic remodeling with endografting after a decade of thoracic endovascular aortic repair experience. J Vasc Surg. 2021;73(3):844-9.
Chen SW, Zhong YL, Qiao ZY, Li CN, Ge YP, Qi RD, et al. One-stage hybrid procedure for distal aortic arch disease: mid-term experience at a single center. J Thorac Dis. 2020;12(12):7117-26.
Ricotta JJ 2nd. Endoleak management and postoperative surveillance following endovascular repair of thoracic aortic aneurysms. J Vasc Surg. 2010;52(4 Suppl):91S-9S.
Deniz G, Kasımzade F, Ozcınar E, Yazicioglu L, Eryılmaz S. Long-term outcomes of TEVAR for thoracic aortic diseases: a retrospective single-center study. J Cardiothorac Surg. 2024;19(1):405.
Johansson G, Markström U, Swedenborg J. Ruptured thoracic aortic aneurysms: a study of incidence and mortality rates. J Vasc Surg. 1995;21(6):985-8.
Gouveia E Melo R, Silva Duarte G, Lopes A, Alves M, Caldeira D, Fernandes E Fernandes R, et al. Incidence and prevalence of thoracic aortic aneurysms: a systematic review and meta-analysis of population-based studies. Semin Thorac Cardiovasc Surg. 2022;34(1):1-16.
Moulakakis KG, Lazaris AM, Georgiadis GS, et al. A Greek multicentre study assessing the outcome of late rupture after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2024;67(5):756-64.
Jones M, Faris P, Moore R. Mortality and risk factors for ruptured abdominal aortic aneurysm after repair endovascular (rARE). J Vasc Surg Cases Innov Tech. 2023;9(3):101165.
Peterson BG. Conduits and endoconduits, percutaneous access. J Vasc Surg. 2010;52(4 Suppl):60S-4S.
Giannopoulos S, Malgor RD, Sobreira ML, Siada SS, Rodrigues D, Al-Musawi M, et al. Iliac conduits for endovascular treatment of aortic pathologies: a systematic review and meta-analysis. J Endovasc Ther. 2021;28(4):499-509.
Zuccon G, D'Oria M, Gonçalves FB, Fernandez-Prendes C, Mani K, Caldeira D, et al. Incidence, risk factors, and prognostic impact of type Ib endoleak following endovascular repair for abdominal aortic aneurysm: scoping review. Eur J Vasc Endovasc Surg. 2023;66(3):352-61.
Cassagnes L, Pérignon R, Amokrane F, et al. Aortic stent-grafts: endoleak surveillance. Diagn Interv Imaging. 2016;97(1):19-27.
Stoecker J, Glaser J. Review of type III endoleaks. Semin Intervent Radiol. 2020;37:371-6.
Candell L, Tucker LY, Goodney P, Walker J, Okuhn S, Hill B, et al. Early and delayed rupture after endovascular abdominal aortic aneurysm repair in a 10-year multicenter registry. J Vasc Surg. 2014;60(5):1146-53.
Oderich GS, Huang Y, Harmsen WS, Tenorio ER, Schanzer A, Timaran CH, et al.; United States Aortic Research Consortium. Early and late aortic-related mortality and rupture after fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms: a prospective multicenter cohort study. Circulation. 2024;150(17):1343-53.
Katsargyris A, Marques de Marino P, Hasemaki N, Nagel S, Botos B, Wilhelm M, et al. Editor's choice - single centre midterm experience with primary fenestrated endovascular aortic aneurysm repair for short neck, juxtarenal, and suprarenal aneurysms. Eur J Vasc Endovasc Surg. 2023;66(2):160-6.
Antoniou GA, Georgiadis GS, Antoniou SA. Late rupture of abdominal aortic aneurysm after previous endovascular repair: a systematic review and meta-analysis. J Endovasc Ther. 2015;22(5):734-44.
Wanhainen A, Van Herzeele I, Bastos Goncalves F, Bellmunt Montoya S, Berard X, Boyle JR, et al. European Society for Vascular Surgery (ESVS) 2024 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur J Vasc Endovasc Surg. 2024;67(2):192-331.
Criado FJ. Iliac arterial conduits for endovascular access: technical considerations. J Endovasc Ther. 2007;14(3):347-51.
Gupta PK, Sundaram A, Kent KC. Morbidity and mortality after use of iliac conduits for endovascular aortic aneurysm repair. J Vasc Surg. 2015;62(1):22-6.
Weidauer S, Nichtweiss M, Hattingen E, Berkefeld J. Spinal cord ischemia: aetiology, clinical syndromes and imaging features. Neuroradiology. 2015;57:241-57.
Spanos K, Kölbel T, Kubitz JC, Wipper S, Konstantinou N, Heidemann F, et al. Risk of spinal cord ischemia after fenestrated or branched endovascular repair of complex aortic aneurysms. J Vasc Surg. 2019;69(2):357-66.
Rinaldi E, Melloni A, Gallitto E, et al. Spinal cord ischemia after thoracoabdominal aortic aneurysms endovascular repair: from the Italian multicenter fenestrated/branched endovascular aneurysm repair registry. J Endovasc Ther. 2023;30(2):281-8.
O'Callaghan A, Mastracci TM, Eagleton MJ. Staged endovascular repair of thoracoabdominal aortic aneurysms limits incidence and severity of spinal cord ischemia. J Vasc Surg. 2015;61(2):347-54.e1.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Juan Moctezuma Vera Flores, José M. Cruz Pérez, José Á. Barajas Colón

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.