Beyond pneumoperitoneum: alternative and innovative uses of the Veress needle — a systematic review

Authors

  • Zita Hornok Independent Researcher
  • Katalin Borbála Potyó Primary Care Health Service, Pápa, Hungary

DOI:

https://doi.org/10.18203/2349-2902.isj20264363

Keywords:

Veress needle, Systematic review, Off-label use, Surgical innovation

Abstract

The Veress needle is a cornerstone of minimally invasive surgery. Originally developed to induce artificial pneumothorax for tuberculosis treatment, it is now primarily recognized for its role in creating pneumoperitoneum. The objective of this study was to systematically summarize the innovative, off-label applications of this device that extend beyond its conventional use in establishing pneumoperitoneum. In accordance with PRISMA 2020 guidelines, a systematic search was conducted on PubMed, Scopus and Cochrane Library databases to identify and categorize documented non-conventional applications of the Veress needle. Methodological quality was assessed using the Mixed Methods Appraisal Tool. A total of 54 studies met the inclusion criteria and were included in the qualitative synthesis. The included studies were categorized into four domains: surgical access and technical assistance, thoracic applications and emergency decompression, specialized diagnostic and therapeutic applications, and preclinical and experimental validation. Methodological quality was predominantly moderate (83%), with the majority of reports consisting of case series or case reports. To the best of our knowledge, this is the first systematic review highlighting how this nearly century-old invention has evolved into a versatile, multifunctional tool in modern minimally invasive surgery.

References

Veress J. A needle for the safe use of pneumoperitoneum. Gastroenterologia. 1961;96:150-152. [German].

Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71.

Hong QN, Fàbregues S, Bartlett G, Boardman F, Cargo M, Gramatikov P, et al. The Mixed Methods Appraisal Tool (MMAT) version 2018 for information professionals and researchers. Educ Inf. 2018;34:285-291.

Campbell M, McKenzie JE, Sowden A, Katikireddi SV, Brennan SE, Ellis S, et al. Synthesis without meta-analysis (SWiM) in systematic reviews: reporting guideline. BMJ. 2020;368:l6890.

Giampaolino P, Pellicano M, Tommaselli GA, Bifulco G, Simioli S, Nappi C, et al. In-office transvaginal hydrolaparoscopy: a step-by-step, intraoperative pain evaluation. Arch Gynecol Obstet. 2015;292:1373-1377.

Gordts S, Campo R, Brosens I. Office transvaginal hydrolaparoscopy for early diagnosis of pelvic endometriosis and adhesions. J Am Assoc Gynecol Laparosc. 2000;7:45-49.

Gordts S, Campo R, Rombauts L, Brosens I. Transvaginal salpingoscopy: an office procedure for infertility investigation. Fertil Steril. 1998;70:523-526.

Zhang CJ, Chen RF, Zhu HT, Wen RM, Xue S, Li W, et al. Closed technique for the creation of retroperitoneal working space for symptomatic renal cysts. Minim Invasive Ther Allied Technol. 2013;22:110-115.

Asif A, Tawakol J, Khan T, Vieira CF, Byers P, Gadalean F, et al. Modification of the peritoneoscopic technique of peritoneal dialysis catheter insertion: experience of an interventional nephrology program. Semin Dial. 2004;17:171-173.

Jaroszyński A, Miszczuk J, Jadach M, Głuszek S, Dąbrowski W. A new, safe, and effective technique for percutaneous insertion of a peritoneal dialysis catheter. J Clin Med. 2024;13(9):2618.

Ma Y, Liu S, Yang M, Zou Y, Xue D, Liu Y, et al. Association between different peritoneal dialysis catheter placement methods and short-term postoperative complications. BMC Nephrol. 2021;22(1):151.

Napoli M, Russo F, Mastrangelo F. Placement of peritoneal dialysis catheter by percutaneous method with the Veress needle. Adv Perit Dial. 2000;16:165-9.

Babu R, Arora A, Raj N. Stenting antegrade via Veress needle during laparoscopic pyeloplasty (SAVVY technique). J Indian Assoc Pediatr Surg. 2019;24:117-9.

Bishmanov R, Alchinbayev M. Simplified stenting methods during laparoscopic pyeloplasty in children. Electron J Gen Med. 2020;17(5):em236.

Chandrasekharam VVS, Khyati Kiran J, Uday Bhaskar MNS, Phani A. Novel use of the Veress needle for percutaneous retrograde ureteral access after Cohen reimplantation in children. J Pediatr Urol. 2025;21:1947-9.

Ertekin SC, Akbulut G, Turgut E, Akyol H, Ergenç M, Yeğen C. Evaluation of Veress needle as a liver retraction technique in laparoscopic sleeve gastrectomy. Surg Innov. 2025;32:85-93.

Gianni S, De Luca M, Oscar B, Andrea C, Luca B, David A, et al. Veress needle: a simple liver retraction technique for lap band positioning in single-incision laparoscopic surgery (SILS). Obes Surg. 2012;22(1):190-1.

Tatekawa Y. Laparoscopic extracorporeal ligation of hernia defects using an epidural needle and preperitoneal hydrodissection. J Endourol. 2012;26:474-477.

Desai MM, Stein R, Rao P, Canes D, Aron M, Rao PP, et al. Embryonic natural orifice transumbilical endoscopic surgery (E-NOTES) for advanced reconstruction: initial experience. Urology. 2009;73:182-7.

Leeds IL, Barbon C, Beatty CA, Wolfgang CL. Surgical intervention for a foreign body trapped in the stomach. Am Surg. 2015;81(3):E115-6.

Kotakala BK, Mishra RK. Veress needle for port-site closure. World J Lap Surg. 2015;8:39-42.

Ranjani CM, Anish P. A comparative study between hand suture and Veress needle technique closure of port sites in laparoscopic surgeries. Int J Acad Med Pharm. 2026;8:761-765.

Favelier S, Guiu S, Cherblanc V, Cercueil JP, Krausé D, Guiu B. Transthoracic adrenal biopsy procedure using artificial carbon dioxide pneumothorax as outpatient procedure. Cardiovasc Intervent Radiol. 2013;36:1184-1187.

Maeda H, Kajiwara K, Yoshimatsu R, Yamanishi T, Minamiguchi H, Karashima T, et al. Artificially induced pneumothorax with a Veress needle for cryoablation of renal cell carcinoma. Minim Invasive Ther Allied Technol. 2022;31(3):483-6.

Iqbal SI, Molgaard C, Williamson C, Flacke S. Purposeful creation of a pneumothorax and chest tube placement to facilitate CT-guided coil localization of lung nodules before video-assisted thoracoscopic surgical wedge resection. J Vasc Interv Radiol. 2014;25:1133-1138.

Sabatella L, Aliseda D, Martí-Cruchaga P, Zozaya G, López-Olaondo L, Blanco Asensio N, et al. Controlled capnothorax creation for stapled diaphragm resection: a safe maneuver for en-bloc liver and phrenic resection without diaphragm opening. Surg Endosc. 2026;40:4484-4490.

Huan NC, Kho SS, Nyanti LE, Ramarmuty HY, Rahim MAA, Ho RL, et al. Dry medical thoracoscopy with artificial pneumothorax induction using Veress needle. Tuberc Respir Dis (Seoul). 2025;88:181-189.

Hendrickson RJ, Rothenberg SS, Partrick DA, Bensard DD. Thoracostomy in children utilizing a minimally invasive technique. Pediatr Endosurg Innov Tech. 2004;8(3):241-4.

Soldati G, Smargiassi A, Inchingolo R, Sher S, Valente S, Corbo GM. Ultrasound-guided pleural puncture in supine or recumbent lateral position: feasibility study. Multidiscip Respir Med. 2013;8(1):18.

Johnson S, McCracken J, Baidoun F. Tension pneumoperitoneum after bystander cardiopulmonary resuscitation: a case report. Int J Surg Case Rep. 2018;42:227-232.

Jenkins DW Jr, McKinney MK, Szpak MW, Booker JL Jr. Veress needle in the pleural space. South Med J. 1983;76:1383-1385.

Kurian AA, Dunst CM, Sharata A, Bhayani NH, Reavis KM, Swanström LL. Peroral endoscopic esophageal myotomy: defining the learning curve. Gastrointest Endosc. 2013;77(5):719-25.

Rathinam S, Grobler S, Bleetman A, Kink T, Steyn R. Evolved design makes ThoraQuik safe and user friendly in the management of pneumothorax and pleural effusion. Emerg Med J. 2014;31:59-64.

Lockhart CM, Gerding RL, Imbembo AL, Shuck JM. Percutaneous peritoneal lavage using the Veress needle: a preliminary report. J Trauma. 1987;27:1181-1185.

Saunders CJ, Battistella FD, Whetzel TP, Stokes RB. Percutaneous diagnostic peritoneal lavage using a Veress needle versus an open technique: a prospective randomized trial. J Trauma. 1998;44:883-888.

Nau P, Anderson J, Needleman B, Ellison EC, Melvin WS, Hazey JW. Endoscopic peritoneal access and insufflation: natural orifice transluminal endoscopic surgery. Gastrointest Endosc. 2010;71(3):485-9.

Ehrlich PF, Teitelbaum DH, Hirschl RB, Rescorla F. Excision of large cystic ovarian tumors: combining minimally invasive surgery techniques and cancer surgery—the best of both worlds. J Pediatr Surg. 2007;42(5):890-3.

Kilincaslan H, Cipe G, Aydogdu I, Sarac F, Toprak H, Ari E. Pure laparoscopic management of a giant ovarian cyst in an adolescent. Am J Case Rep. 2014;15:4-6.

Seshadri PA, Poulin EC, Mamazza J, Schlachta CM. Needlescopic decapsulation of a splenic epithelial cyst. Can J Surg. 2000;43:303-5.

Bhansakarya R, Subedi S. Laparoscopic management of large right paratubal cyst: a case report. JNMA J Nepal Med Assoc. 2020;58(227):501-4.

Ekwunife CN, Amadi EC. Laparoscopy-guided liver abscess drainage: an additional use of Veress needle. J Surg Tech Case Rep. 2012;4(1):36-8.

Mazzocchi M, Dessy LA, Marchetti F, Marchetti F, Carlesimo B. The use of the Veress needle to drain mammary periprosthetic fluid. In Vivo. 2010;24(2):219-22.

Lund L, Yeung CK. Periurethral injection therapy for urinary incontinence using a laparoscopic port. J Endourol. 2003;17(7):493-5.

Menczer J. Use of the Veress needle for instillation of intraperitoneal chemotherapy. Gynecol Oncol. 1995;59(2):249-50.

Pfeiffer P, Asmussen L, Kvist-Poulsen H, Bertelsen K. Intraperitoneal chemotherapy: introduction of a new single-use delivery system: a preliminary report. Gynecol Oncol. 1989;35:47-49.

Holcomb JB, McManus JG, Kerr ST, Pusateri AE. Needle versus tube thoracostomy in a swine model of traumatic tension hemopneumothorax. Prehosp Emerg Care. 2009;13(1):18-27.

Leatherman ML, Held JM, Fluke LM, McEvoy CS, Inaba K, Grabo D, et al. Relative device stability of anterior versus axillary needle decompression for tension pneumothorax during casualty movement: preliminary analysis of a human cadaver model. J Trauma Acute Care Surg. 2017;83(1 Suppl 1):S136-41.

Leatherman ML, Fluke LM, McEvoy CS, Pokorny DJ, Ricca RL, Martin M, et al. Bigger is better: comparison of alternative devices for tension hemopneumothorax and pulseless electrical activity in a Yorkshire swine model. J Trauma Acute Care Surg. 2017;83(6):1187-94.

Lubin D, Tang AL, Friese RS, Martin M, Green DJ, Jones T, et al. Modified Veress needle decompression of tension pneumothorax: a randomized crossover animal study. J Trauma Acute Care Surg. 2013;75(6):1071-5.

McEvoy CS, Leatherman ML, Held JM, Fluke LM, Ricca RL, Polk T. Larger-caliber alternative devices for decompression of tension hemopneumothorax in the setting of hemorrhagic shock. J Spec Oper Med. 2018;18(4):18-23.

Marecos MC, Torres RA, Bailez MM, Vagni RL, Klappenbach RF. Pediatric thoracoscopic training in an experimental pleural empyema rabbit model. J Laparoendosc Adv Surg Tech A. 2006;16(4):397-9.

Sharata A, Aliabadi-Wahle S, Bhayani NH, Kurian AA, Reavis KM, Dunst CM, et al. Subxyphoid thyroidectomy: a feasibility study. Surg Innov. 2014;21(2):194-7.

Kumthekar RN, Opfermann JD, Mass P, Contento JM, Berul CI. Percutaneous epicardial pacing in infants using direct visualization: a feasibility animal study. J Cardiovasc Electrophysiol. 2023;34(6):1452-8.

Alshiek J, Marroquin J, Shobeiri SA. Vaginal ultrasound-guided pouch of Douglas robotic entry in a live ovine model and human female cadaveric specimens. J Robot Surg. 2022;16(1):73-9.

Meining A, Wilhelm D, Burian M, Dundoulakis M, Schneider A, von Delius S, et al. Development, standardization, and evaluation of NOTES cholecystectomy using a transsigmoid approach in the porcine model: an acute feasibility study. Endoscopy. 2007;39:860-4.

Sühn T, Pandey A, Friebe M, Illanes A, Boese A, Lohmann C. Acoustic sensing of tissue-tool interactions: potential applications in arthroscopic surgery. Curr Dir Biomed Eng. 2020;6:595-8.

Guarner-Argente C, Córdova H, Martínez-Pallí G, Navarro-Ripoll R, Rodríguez-d'Jesús A, de Miguel CR, et al. Gastrotomy closure with a new tissue anchoring device: a porcine survival study. World J Gastroenterol. 2011;17(13):1732-8.

Morozov A, Kalinin N, Androsov A, Gazimiev A, Lerner Y, Gomez Rivas J, et al. A novel and less traumatic needle for kidney puncture: development and preclinical study results. J Endourol. 2023;37(1):93-8.

Downloads

Published

2026-11-25

How to Cite

Hornok, Z., & Potyó, K. B. (2026). Beyond pneumoperitoneum: alternative and innovative uses of the Veress needle — a systematic review. International Surgery Journal, 13(12), 2536–2545. https://doi.org/10.18203/2349-2902.isj20264363

Issue

Section

Systematic Reviews