Inadvertent catheter placement into the innominate artery successfully repaired with perclose

Authors

  • Catherine Kilada Department of Surgery, Flushing Hospital Medical Center, Queens, NY, USA
  • Mina Guerges Department of Vascular Surgery, Jamaica Hospital Medical Center, Queens, NY, USA

DOI:

https://doi.org/10.18203/2349-2902.isj20263856

Keywords:

Central Venous Catheters, Perclose, Endovascular Repair, Innominate Arter

Abstract

Inadvertent arterial catheterization during central venous access is an uncommon but potentially catastrophic complication, with reported incidence ranging from 0.1% to 1%, depending on technique and patient factors. Injuries involving non-compressible, large-caliber vessels such as the brachiocephalic (innominate) artery are particularly high risk due to the potential for hemorrhage, stroke, pseudoaneurysm formation, and mediastinal hematoma. Historically, management has favored open surgical repair, especially for supra-aortic trunk injuries; however, this approach carries significant morbidity in elderly and medically complex patients.1 With advances in endovascular techniques, less invasive strategies including covered stent placement and percutaneous suture-mediated closure devices have emerged as viable alternatives. Recent literature supports the use of suture-mediated closure systems, such as Perclose, in select cases of iatrogenic arterial injury, demonstrating high technical success rates and low complication profiles when appropriate imaging, wire access, and procedural planning are employed.1 These approaches are particularly advantageous in anatomically challenging or surgically hostile fields. We present a case of inadvertent catheterization of the brachiocephalic artery during tunnelled infusion port placement, successfully managed with percutaneous suture-mediated closure. This case highlights the growing role of minimally invasive techniques in the management of central arterial injuries and underscores the importance of early recognition, detailed imaging evaluation, and multidisciplinary coordination. A review of the literature highlights growing evidence supporting endovascular approaches for inadvertent supra-aortic arterial cannulation. Reported success rates of suture-mediated closure devices range from 90–100% in select patients, with reduced morbidity compared to open repair.1-7 This case demonstrates the feasibility, safety, and efficacy of percutaneous closure for innominate artery injury, reinforcing a paradigm shift toward minimally invasive management.

References

Pikwer A, Acosta S, Kölbel T, Malina M, Sonesson B, Åkeson J. Management of inadvertent arterial catheterisation associated with central venous access procedures. Eur J Vasc Endovasc Surg. 2009;38(6):707-14.

Giagtzidis I, Soteriou A, Papadimitriou C, Papoutsis I, Karkos C. Use of a closure device for the management of inadvertent placement of a central venous catheter in the carotid artery: a case report and literature review. Cureus. 2023;15(2):e34911.

Kent J, Zarifa R, Pocivavsek L. Usage of a percutaneous closure device to repair an iatrogenic subclavian artery injury. Vascular. 2023;31(3):585-8.

Gashti M, Radecke JM, Curvin M. Inadvertent innominate artery puncture repair. Endovascular Today. 2010;9(10):34,36,38.

Kim SE, Cho Y, Park SH. Novel approach to managing inadvertent arterial placement of central venous catheters: report of two cases and review of the literature. J Korean Soc Radiol. 2025;86(6):1064-71.

Discalzi A, Maglia C, Ciferri F, Mancini A, Gibello L, Calandri M, et al. Percutaneous closure of accidentally subclavian artery catheterization: time to change first line approach? CVIR Endovasc. 2022;5:23.

AlSheikh S, Aldossary MY, Najeeb R, Alwehaibi NS, Iqbal K. Management of arterial trauma during central venous catheter insertion using a percutaneous suture-mediated closure device (Perclose ProGlide): a report of two cases and literature review. Signa Vitae. 2023;19(6):201-6.

Lenhart L, Loizides A, Galijasevic M, Lutz M, Freund M, Gizewski ER, et al. Minimally invasive management of subclavian artery catheter misplacement: the new standard? J Clin Med. 2025;14(8):2650.

Kania T, Kimyaghalam A, Scarsella J, Guerges M, Breier Y, Deitch J, et al. Supra-aortic arterial injuries following central venous catheterization managed with percutaneous closure devices: a comprehensive literature review of current evidence. Ann Vasc Surg. 2023;96:301-7.

Downloads

Published

2026-10-27

How to Cite

Kilada, C., & Guerges, M. (2026). Inadvertent catheter placement into the innominate artery successfully repaired with perclose. International Surgery Journal, 13(11), 2227–2229. https://doi.org/10.18203/2349-2902.isj20263856

Issue

Section

Case Reports