Robotic-assisted video-assisted thoracic surgery decortication using the Cambridge medical robotics versius system in a chronic kidney disease patient

Authors

  • Ved Prakash Department of General Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana, India
  • Anirudh Agrawal Department of General Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana, India
  • Ashutosh Pandey Department of General Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana, India
  • Shivangi Department of General Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana, India

DOI:

https://doi.org/10.18203/2349-2902.isj20253050

Abstract

Empyema thoracis in patients with chronic kidney disease (CKD) presents a unique therapeutic challenge due to increased bleeding risk and impaired host immunity. This report presents a case of a 45-year-old male on hemodialysis with right-sided multiloculated empyema who underwent robotic-assisted video-assisted thoracic surgery (VATS) decortication using the Cambridge medical robotics (CMR) versius system. The procedure was successfully completed with minimal blood loss, no intraoperative complications, and favorable postoperative recovery. The patient was re-listed for renal transplant after recovery. Robotic-assisted decortication using the CMR versius platform proved to be a safe and effective modality for complex thoracic interventions in high-risk patients.

Metrics

Metrics Loading ...

References

Veronesi G. Robotic surgery for thoracic tumors: future or present? Eur J Cardiothorac Surg. 2021;59(4):727-35.

Kent M, Mandrekar S. Robotic thoracic surgery: a comprehensive review. Ann Thorac Surg. 2020;110(3):987-93.

Abbas AE. Surgical management of pleural space infections. Thorac Surg Clin. 2012;22(1):73-86.

Dixon F, Khanna A, Vitish-Sharma P, Singh NS, Nakade K, Singh A, et al. Initiation and feasibility of a multi-specialty minimally invasive surgical programme using a novel robotic system: A case series. Int J Surg. 2021;96:106182. DOI: https://doi.org/10.1016/j.ijsu.2021.106182

Emmert A, Straube C, Buentzel J, Roever C. Robotic versus thoracoscopic lung resection: A systematic review and meta-analysis. Medicine (Baltimore). 2017;96(35):e7633. DOI: https://doi.org/10.1097/MD.0000000000007633

Sharma A, et al. Initial experience of versius robotic system in minimal access surgery. J minim access surg. 2023;19(2):144-9.

Maskell NA, et al. Uk guidelines for the management of pleural infection in adults. Thorax. 2003;58 suppl 2:ii18–ii28. DOI: https://doi.org/10.1136/thx.58.suppl_2.ii18

Downloads

Published

2025-09-25

How to Cite

Prakash, V., Agrawal, A., Pandey, A., & Shivangi. (2025). Robotic-assisted video-assisted thoracic surgery decortication using the Cambridge medical robotics versius system in a chronic kidney disease patient . International Surgery Journal, 12(10), 1866–1869. https://doi.org/10.18203/2349-2902.isj20253050

Issue

Section

Case Reports