Abstract

Background: Thyroidectomy is one of the most commonly performed surgeries throughout the world which has an extremely low morbidity rate. Nowadays with the advent of newer techniques the duration of surgery and complications have decreased. Conventionally Thyroidectomy was done by suture knot tying technique which needs large number of surgical ties and also time consuming. It decreases healing as well as increases wound infection, injury to neighboring structures and foreign body reaction.

Methods: In this study, I selected 50 patients with thyroid swelling attending the surgery outpatient department from February 2015 to August 2015. Thyroid surgery was done using bipolar cautery. The results were analyzed.

Results: This study shows most of the patients belong to 30-40 years followed by 40-50 years. The male: female ratio is 1:25. Time duration varies from 50 minutes to 135 minutes. The longer duration of surgery compared to other studies is attributed to learning curve. We started using bipolar diathermy since 2013. The blood loss ranges from 25-50 ml. Complication rates are also less with bipolar thyroidectomy, 2% had postoperative hemorrhage, 2% developed temporary RLN palsy, 2% developed minor degree of wound infection, and 6% developed signs and symptoms of hypocalcemia. The mean duration of hospital stay was 4 days.

Conclusions: Thyroidectomy using bipolar cautery is safe and effective method and also less time consuming. The cost of the bipolar cautery is less compared to harmonic scalpel and LigaSure. Bipolar cautery is available in our government hospital. Blood loss using Bipolar Cautery is less compared to conventional Knot–tying technique. The post-operative complications are less with bipolar cautery.

Metrics

Metrics Loading ...

Author Biographies

Vasuki R., Department of General Surgery, Kilpauk Medical College and Hospital, Chennai, Tamilnadu, India

Professor, Department of General Surgery, Kilpauk Medical College and Hospital, Chennai-10.

Thanmaran N. B., Department of General Surgery, Kilpauk Medical College and Hospital, Chennai, Tamilnadu, India

Assistant Professor, Department of General Surgery, Kilpauk Medical College and Hospital, Chennai-10.

Malathi V., Department of General Surgery, Kilpauk Medical College and Hospital, Chennai, Tamilnadu, India

Assistant Professor, Department of General Surgery, Kilpauk Medical College and Hospital, Chennai-10.

Lizrose Kujur, Department of General Surgery, Kilpauk Medical College and Hospital, Chennai, Tamilnadu, India

Junior Resident, Department of General Surgery, Kilpauk Medical College and Hospital , Chennai-10.

References

Vesely DL, Angtuaco EJ, Boyd CM. Sinus tract in the neck: a rare complication of subtotal thyroidectomy for Graves’ disease. J Med. 1986;17(3-4):253-61.

Bailey and Love’s short practice of surgery, the principles of diathermy, 26th edition. Edited by N. S. Williams, C. J. K. Bulstrode and P.R O' Connell. Boca Raton FL CRC Press; 2013.ISBN-13:100:761.

King TT, Worple R. Self-irrigating bipolar diathermy forceps. J Neurosurg. 1972;37:246-7.

Dujovny M, Vas R, Osgood CP. Bipolar jeweler's forceps with automatic irrigation for coagulation in microsurgery. Plast Reconstr Surg. 1975;56:585-91

Malis LI. Electrosurgery and bipolar technology. Neurosurgery. 2006;58(Suppl 1):1-12.

Sakatani K, Ohtaki M, Morimoto S, Hashi K. Isotonic mannitol and the prevention of local heat generation and tissue adherence to bipolar diathermy forceps tips during electrical coagulation: Technical note. J Neurosurg. 1995;82:669.

Govindaraj E, Meti RM, Ravikiran HR. A study of use of bipolar cautery in thyroidectomy for coagulating vascular pedicles instead of conventional ligation. Inter J Biomed Res. 2015;6(6):382-4.

Manouras A, Markogiannakis H, Koutras AS. Thyroid surgery: comparison between the electro thermal bipolar vessel sealing system, harmonic scalpel and classic suture ligation. Am J Surg. 2008;195(1):48-52.

Sandonato L, Cipolla C, Graceffa G, Fricano S, Li Petri S, Prinzi G, et al. Bipolar electro thermic coagulation (ligasure bipolar vessel sealing system) in thyroid surgery. Chir Ital. 2003;55(3):411-5.

Challa S, Surapaneni S. Suture less thyroidectomy vascular control using bipolar electro thermal cautery, J Evol Med Dent Sci. 2012;1(6):1083-6.

Bove A, Papanikolaou IG, Bongarzoni G, Mattei PA, Markogiannakis H, Chatzipetrou M, et al. Thyroid surgery with harmonic focus, ligasure precise and conventional technique: a retrospective case-matched study. Hippokratia. 2012;16(2):154-9.

Downloads

Published

2017-02-25

How to Cite

R., V., N. B., T., V., M., & Kujur, L. (2017). A study of use of bipolar cautery in thyroidectomy. International Surgery Journal, 4(3), 1059–1064. https://doi.org/10.18203/2349-2902.isj20170862

Issue

Section

Original Research Articles